>On Wed, Feb 04, 2004 at 02:04:04 -0800, Tim Hockin wrote:* GMPI must provide one master clock per graph. The GMPI master clock must provide sufficient range to represent several hours of time at a high sampling rate, and enough resolution to address individual audio samples. Hosts may build multiple graphs with different master clocks.
Shouldnt this be "at least one", theres no reason why the host might not present two different timelines to two different plugins in the same graph - if it wanted to. Isnt the intention that a give plugin should only be presented with one distinct timeline?
the master clock is *not* the same as a timeline. plugin's can be presented with different timelines, but there is only one master clock.
---------------------------------------------------------------------- Generalized Music Plugin Interface (GMPI) public discussion list Participation in this list is contingent upon your abiding by the following rules: Please stay on topic. You are responsible for your own words. Please respect your fellow subscribers. Please do not redistribute anyone else's words without their permission.