He says the set has HV no filament voltage the tubes should have glowing
filaments with the anode lead removed from splitter and put into a glass
container.
 If NO filaments at this point IT'S not the splitter.Repair the Filament
circuit.
Country TV
Ron Miller
Inez, TX. 77968

----- Original Message ----- 
From: "armando guerra" <birdie@xxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Friday, February 20, 2004 5:35 PM
Subject: [TechAssist] Re: Zenith B/S PVR5263RK


> If you remove the lead coming off the flyback into the H.V. divider and
you have high voltage there, then the divider\splitter is bad.Very common
failure.
> Mando
> Birdie's TV & Electronics
> Casa  GRande, AZ
>
> TV Man wrote:
>
> > Unit has sound no picture. The filaments don't light up. I have HV
coming out of the flyback. How do you check the HV on each tube? They seem
to be sealed. I'm guessing the focus block is bad, but before I order one I
wanted to get some input. Thanks, Dave
> > TV Man
> > Inverness, Fl.
> >
>
> --------------------------------------------------------------------------
---