[modeleng] Re: New boiler test rules

  • From: Alan Stepney <alesara2@xxxxxxxxx>
  • To: modeleng@xxxxxxxxxxxxx
  • Date: Sat, 14 Jan 2006 20:03:40 +0000 (GMT)

TWO injectors should be OK.

Funnily enough, lunch time I was reading a report by
the SMEE about loco's being taken to the ME Exhibition
and offered to the SMEE to run on their track there.
They insisted on having two methods of feeding water,
and sometimes found that both were inoperative.

That was 50 years ago.!!!

Alan 
--- Clif Walker <clif.gwr@xxxxxxxxxxxxxx> wrote:

> Hi All,
> 
> That should be fun as I know of a lot of locos that
> only have Injectors as 
> the owners say that hand pumps and axle pumps are
> not prototype.
> 
> Regards
> 
> Clif



                