It's a $1 part. It fails frequently. Why NOT replace it,to avoid Returns ??? Peggs At 06:02 AM 4/6/05, J. Knoll wrote: >I was doing that but after a few returns a month later after the original >repair I started replacing that diode automatically to avoid wasting time >with returns. I hate the 169 and the less time on the bench with one the >better. >Jay-Jays tv >On Apr 6, 2005 8:36 AM, Damon <damon101@xxxxxxxxxxxxxx> wrote: > > > > Actually I monitor CR4118's voltage to determine whether it needs replaced > > or not. > > 14 volts -OK > > > > 12 Volts - Replace > > > > 10 Volts - Bad > > > > and there's a big wide replace area with skinny -OK / Bad sections if you > > want to make a meter out of it....;-) > > > > Yes replacing CR4118 will cover a multitude of problems/intermittants. > > > > Damon Brunger > > Telrad Electronics > > Fort Wayne IN > > ----- Original Message ----- > > From: "Electric Medic" <info@xxxxxxxxxxxxxxxxx> > > To: <techassist@xxxxxxxxxxxxx> > > Sent: Tuesday, April 05, 2005 11:58 PM > > Subject: [TechAssist] Re: [TechAssist]WHAT MODEL OR CHASSIS? Re: > > intermittent rca > > > > > Please put Make, Model (or Chassis), and Problem in subject line. Then > > email > > > can be filed Automatically, Thanks. CR4118 should go without saying. Of > > > course it will fix intermittent operation. That is the first part we > > change > > > on all CTC169's regardless of customers problem. I would think all shops > > > would change this on all CTC169 repairs, we do, don't we? > > > > > > Perry Bower > > > Electric Medic > > > "It's Cheaper to Keep Her" > > > http://www.electricmedic.com > > > 3850 Washington Road Suite 4C > > > Martinez, Georgia 30907 > > > Phone: 706-8MEDIC4 (863-3424) > > > Phone: 706-863-3474 > > > Fax: 706-863-2316 > > > mailto:info@xxxxxxxxxxxxxxxxx > > > > > > > > > -----Original Message----- > > > From: techassist-bounce@xxxxxxxxxxxxx > > > [mailto:techassist-bounce@xxxxxxxxxxxxx]On Behalf Of Gary McCartney > > > Sent: Wednesday, April 06, 2005 12:48 AM > > > To: techassist@xxxxxxxxxxxxx > > > Subject: [TechAssist] Re: intermittant rca > > > > > > > > > Don't know if this will cure it but it has been recommended by many > > > techs to replace CR4118 (RCA # 164590 or FR302 generic)in every CTC169 > > > that comes into the shop, whether it appears to be OK or not. This diode > > > causes a lot of strange symptoms. > > > > > > > > > > > > > > > Gary McCartney > > > > > > McCartney Electronics > > > Guelph Ontario Canada > > > Est. 1984 > > > email: gary (at) number63.ca > > > > > > > > > > > > > > > > > > > > > > > > GRAYSTV@xxxxxxx wrote: > > > > we have a 35 " rca ctc169BG5 that shuts down very intermitantly. like > > > once > > > > a day. I measured the b+ after it shutdown and it did not waver. when > > it > > > > tried to turn on.otherwise i can't get a test. i have replaced > > > > c4102,c4108,c4104,c612,cr4401,c4406,cr4402, c4403, and c4404. does > > anyone > > > have any advice?? > > > > > > > > > > > > > > > > GraysTV/Glenn Gray > > > > Berlin Ht's.OH 44814 > > > > Phone (419) 588-2325 > > > > graystv@xxxxxxx > > > > > > > > > > > > > > > > -------------------------------------------------------------------------- > > > --- > > > > This Email List is Public. Remove: > > http://www.tech-assist.org/remove.htm > > > > Lost Password: http://www.tech-assist.org and select "Login > > Problems?". > > > > Email Archives: //www.freelists.org/archives/techassist/ > > > > > > > > > > > > -------------------------------------------------------------------------- > > -- > > > - > > > This Email List is Public. Remove: http://www.tech-assist.org/remove.htm > > > Lost Password: http://www.tech-assist.org and select "Login Problems?". > > > Email Archives: //www.freelists.org/archives/techassist/ > > > > > > > > -------------------------------------------------------------------------- > > --- > > > This Email List is Public. Remove: http://www.tech-assist.org/remove.htm > > > Lost Password: http://www.tech-assist.org and select "Login Problems?". > > > Email Archives: //www.freelists.org/archives/techassist/ > > > > > > > > > > > > -- > > > Internal Virus Database is out-of-date. > > > Checked by AVG Anti-Virus. > > > Version: 7.0.308 / Virus Database: 266.8.0 - Release Date: 3/21/2005 > > > > > > > > > > > > > ----------------------------------------------------------------------------- > > This Email List is Public. Remove: http://www.tech-assist.org/remove.htm > > Lost Password: http://www.tech-assist.org and select "Login Problems?". > > Email Archives: //www.freelists.org/archives/techassist/ > > > > > > >-- >J. Knoll TechAssist Monitor >TechAssist >225 Monticello Ave. >Clarksburg WV, 26301 >www.tech-assist.org <http://www.tech-assist.org> >www.techassist.net<http://www.techassist.net> >------------------------------------------------------- >PS: >If replying to this email, please include all previous correspondence. >It is the only way we can get the full picture. Thank You!!! > >----------------------------------------------------------------------------- >This Email List is Public. Remove: http://www.tech-assist.org/remove.htm >Lost Password: http://www.tech-assist.org and select "Login Problems?". >Email Archives: //www.freelists.org/archives/techassist/ -- This message has been scanned by the OMU Online postini filter. ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/