[argyllcms] Re: profiling camera

  • From: Iliah Borg <ib@xxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Sun, 7 Aug 2011 09:37:44 -0400

On Aug 7, 2011, at 8:36 AM, nino loss wrote:

> Just changing colprof to -un and -r0 got the values down to peak 0.6  and 
> 0.28! Also I set -al as C1 is expecting LUT with LAB PCS.


With this small number of patches deltaE in no way characterize the profile 
quality. For C1 it is a good adea to create an XYZ  matrix profile and use it 
when color editing is not needed; otherwise to create a LUT Lab profile based 
on that matrix profile.


--
Iliah Borg
ib@xxxxxxxxxxx