[argyllcms] Re: profiling camera

  • From: Marco Noldin <marconoldin@xxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Fri, 5 Aug 2011 08:27:51 +0200

Are not your sampling boxes too much large? Some of them seem to come
out from the patches boundaries. Maybe you can try to change the
BOX_SHRINK value.

Marco

2011/8/5 nino loss <nino@xxxxxxxx>:
> I still get a peak error of 18.381637 and an average of 7.896481 !
>
> nino
>
>
> On 8/5/2011 3:12 AM, nino loss wrote:
>>
>> It worked right now with a new image. I made a tiny little bit wider crop
>> of the target and corrected -0.16% of rotation. A added -a to be sure.
>>
>> Now lets see the next step ;-)
>>
>> nino
>>
>>
>> On 8/5/2011 3:05 AM, nino loss wrote:
>>>
>>> I already tried without success, because of error code 0x3 "Pattern match
>>> wasn't good enough".
>>>
>>>  nino
>>>
>>>
>>> On 8/5/2011 3:03 AM, Graeme Gill wrote:
>>>>
>>>> nino loss wrote:
>>>>>
>>>>> I just noticed that the numbers go the wrong way?!
>>>>
>>>> That would explain it, yes. It's a puzzle why that has happened though.
>>>> You might be able to use the scanin -a flag to fix the problem.
>>>>
>>>> Graeme Gill.
>>>>
>>>
>
>

Other related posts: