[rollei_list] Re: Which Rolleicord

  • From: "Jeffery Smith" <jls@xxxxxxxxxx>
  • To: <rollei_list@xxxxxxxxxxxxx>
  • Date: Wed, 27 Dec 2006 09:03:44 -0600

That's helpful to know. I have two F models and need to check their meter
against a handheld. I'll take some bright and dimmer readings.

Jeffery Smith
New Orleans, LA
http://www.400tx.com
http://400tx.blogspot.com/



-----Original Message-----
From: rollei_list-bounce@xxxxxxxxxxxxx
[mailto:rollei_list-bounce@xxxxxxxxxxxxx] On Behalf Of Richard Knoppow
Sent: Tuesday, December 26, 2006 9:46 PM
To: rollei_list@xxxxxxxxxxxxx
Subject: [rollei_list] Re: Which Rolleicord



----- Original Message ----- 
From: "Jeffery Smith" <jls@xxxxxxxxxx>
To: <rollei_list@xxxxxxxxxxxxx>
Sent: Tuesday, December 26, 2006 4:23 PM
Subject: [rollei_list] Re: Which Rolleicord


Four months ago, I bought a 'brand new' Rolleiflex 2.8F 
Aurum (yes, that
gold plated one with the endangered animal skin covering). I 
haven't taken
it out of its box yet (it was still in the corregated box 
that came from the
factory). I'm going to wait until Harry finishes with my 
Rolleicord and
Rollei 35 before I bog him down with a third camera. I'm 
praying that a
selenium meter that hasn't seen light for several decades 
will still work.

I still cruise ebay for a good deal on an SL66.

Jeffery "Pimp My Ride" Smith
New Orleans, LA
http://www.400tx.com
http://400tx.blogspot.com/

   Just being in the dark does no harm to a Selenium cell. 
What kills them is excessive heat or exposure to moisture. 
The cells are supposed to be sealed but sometimes the seals 
break down with age and moisture can get in. The usual 
symptom is that the meter becomes non-linear, that is, there 
is a progressive error increasing with light intensity. Bad 
cells frequently read low by about one stop for bright light 
_at the cell_. This is easy to check for meters which have 
two ranges with an overlap in between them. A good cell will 
give identical readings on both ranges within the scale 
error of the meter. A bad cell will give a significantly 
lower reading on the low range than the high range.

---
Richard Knoppow
Los Angeles, CA, USA
dickburk@xxxxxxxxxxxxx 

---
Rollei List

- Post to rollei_list@xxxxxxxxxxxxx

- Subscribe at rollei_list-request@xxxxxxxxxxxxx with 'subscribe' 
in the subject field OR by logging into www.freelists.org

- Unsubscribe at rollei_list-request@xxxxxxxxxxxxx with 
'unsubscribe' in the subject field OR by logging into www.freelists.org

- Online, searchable archives are available at
//www.freelists.org/archives/rollei_list



---
Rollei List

- Post to rollei_list@xxxxxxxxxxxxx

- Subscribe at rollei_list-request@xxxxxxxxxxxxx with 'subscribe' 
in the subject field OR by logging into www.freelists.org

- Unsubscribe at rollei_list-request@xxxxxxxxxxxxx with 
'unsubscribe' in the subject field OR by logging into www.freelists.org

- Online, searchable archives are available at
//www.freelists.org/archives/rollei_list

Other related posts: