[gmpi] Re: Parameters / controls / GMPI event system - refreshment

  • From: Jeff McClintock <jeffmcc@xxxxxxxxxx>
  • To: gmpi@xxxxxxxxxxxxx
  • Date: Fri, 02 Dec 2005 09:07:54 +1300

>  Two RealVoices are now playing.
>  One VVID is ACTIVE, one VVID is in RELEASE.

Yeah, but again, that is the wrong behavoir.

Play the same piano key twice, you do *not* hear the decay of one note *and* the attack of the 2nd at the same time. It's not physically possible and any Software piano emulates that.

The synth needs to stop the leisurly decay of the first G and shut it off *fast* ( ~ 1ms ).

The best way to indicate the 2nd G should *replace* the 1st immediately is to re-use the VVID.

Yes?

This behavior applies even when you play other notes between the two Gs. The logical conclusion is:
-Always use the same VVID for that G key... or in general


For a keyboard instrument: Give each key a unique VVID and stick with it.

Best regards,
Jeff


---------------------------------------------------------------------- Generalized Music Plugin Interface (GMPI) public discussion list Participation in this list is contingent upon your abiding by the following rules: Please stay on topic. You are responsible for your own words. Please respect your fellow subscribers. Please do not redistribute anyone else's words without their permission.

Archive: //www.freelists.org/archives/gmpi
Email gmpi-request@xxxxxxxxxxxxx w/ subject "unsubscribe" to unsubscribe

Other related posts: