Terminating at both ends squares the attenuation of reflections that result from the non-ideal case. This greatly relieves the tolerances required to achieve acceptable intersymbol interference. Steve. On 8/9/2011 1:26 AM, Rajan Hansa wrote: > Experts, > > Can anyone explain that why in some designs we see source as well as load > terminations, I mean termination at both side of traces ? If ringing is a > issue then only source termination should be sufficient to control it and we > can use a receiver with very high input impedance i.e. no need to match > input impedance of receiver with transmission line characteristics > impedance. > > Rajan > > > ------------------------------------------------------------------ > To unsubscribe from si-list: > si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field > > or to administer your membership from a web page, go to: > //www.freelists.org/webpage/si-list > > For help: > si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field > > > List technical documents are available at: > http://www.si-list.net > > List archives are viewable at: > //www.freelists.org/archives/si-list > > Old (prior to June 6, 2001) list archives are viewable at: > http://www.qsl.net/wb6tpu > > > -- Steve Weir IPBLOX, LLC 150 N. Center St. #211 Reno, NV 89501 www.ipblox.com (775) 299-4236 Business (866) 675-4630 Toll-free (707) 780-1951 Fax ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http://www.si-list.net List archives are viewable at: //www.freelists.org/archives/si-list Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu