[SI-LIST] Re: Why Termination at Both End ?

  • From: Sen Velmurugan <sen.velmurugan@xxxxxxxxxx>
  • To: si-list@xxxxxxxxxxxxx
  • Date: Mon, 22 Aug 2011 16:17:41 -0700

Rajan, When you need Xohm termination to sink a current source, you can 
use 2Xohm termination each at source and destination.
This way source see, 2X || 2X = X ohm sink and voltage at load is 
"cleaner". Basically, you have more freedom of choice to play with.

~Sen.Velmurugan@xxxxxxxxxx


------------------------------------------------------------------