Hi all! I will list the work so far: 15 V standby = 14.2 5V standby =4.9V Raw B+=151V Regulated B+ is too high I think ...The meter does not like the signal at TP4101 some times 197V sometimes 1.97V?? Should the Reg B+ be 143V before turn on???? From cathode of CR4106 to Cathode of CR4101 first I had 2 Volts.... Now after changing diodes I get 3 volts??? Should be under 1 Volt. Installed a startup kit from Global Q4101, U4101, C4102, C4118, C4108 (47uf) which also was a 47UF before. My schematic shows 39uf ?? does this make a difference?? Caps were installed first with Q4101 , IC U4101 was installed afterwards. Also changed C4104(15uf) with also no change. I also tried to isolate the H out (curiosity) - no change I've read many tips but most of these point to the parts that I've already changed. Can someone brush up my 169 skills. What am I missing?? Does anyone have a troubleshooting flow chart for the 169?? This would help. BTW when you push the on button you can see the front led give a slight single blink. TIA all ! All tips and comments welcome. ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/