Hi, Sorry for the length of this. Here's what I have. This is a service call job on a WS-55311 (Chassis #V20C). It was throwing an error code 22 (Short protect). I measured a dead short on the -24V line, which feeds the convergence output. When I removed the Heat sink from the convergence outputs, I found that too much heat sink compound had been applied to the chips, and had seeped down onto the board. This was the cause of my short. I replaced the convergence IC's, and now I'm getting a code 23 (Horizontal Deflection Failure). The 110V supply is OK. I assume that I have deflection, since I'm reading HV drive to the power board. I double checked that I had replugged everything. Has anyone had any code 23 problems with these? Any ideas will be appreciated. Thanks, John Myers Myers TV Service Alliance, OH myers_tv_b@xxxxxxxxxxxxx www.myerstv.net ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Appliance Repair List: http://www.tech-assist.org/secure/tip/chatjoin.htm#app Email Archives: //www.freelists.org/archives/techassist/