Ken  you may be interested in looking at a presentation made by 
Dr Bogatin that addressed this very subjecy. 
you can find it at http://www.ieee.org/rmcemc go to the archives
and look for the 2003 December meeting.

Cheers

Best Regards
Charles Grasso
Senior Compliance Engineer
Echostar Communications Corp.
Tel:  303-706-5467
Fax: 303-799-6222
Cell: 303-204-2974
Email: charles.grasso@xxxxxxxxxxxx;  
Email Alternate: chasgrasso@xxxxxxxx
 

-----Original Message-----
From: Ken Hayden [mailto:khayden@xxxxxxxxxxxxxxxxxx] 
Sent: Friday, January 30, 2004 6:00 AM
To: MikonCons@xxxxxxx
Cc: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] Re: Traces don't cause EMI - really?

I read this thread last fall with great interest, and I think I learned a
lot.  But I
have an immediate application about which I'm still confused, and could use
some help.

This application is for a PCB that will be assembled into a shielded card
cage
assembly.  This particular PCB will not have any cables leaving the shielded
enclosure,
but any number of other PCBs in this 36-card assembly could have cables of
various
geometries and filtering characteristics.  (This is a telecom/datacom
application, and
the PCBs are line cards with numerous flavors of DSL, Ethernet, POTS, and
digital
telecom interfaces.)

We have traditionally laid out PCBs for this application with outside
planes, and
absolutely everthing with any high-frequency content was run on inside
signal layers.
Using this kind of stackup, and taking many of the usual precautions, we
have had good
success in building cards that pass FCC class A, and usually class B.

In the current (very quick-turn) project, we will be using an embedded
microprocessor we
haven't used before.  In the interest of building fully functional boards
with good
signal and power integrity as quickly as possible, we are considering
directly lifting
the processor, DDR SDRAM, gigabit GMII, PCI, and HyperTransport artwork
section from the
microprocessor vendor's evaluation kit artwork, and incorporating the
artwork into the
rest of our design.

It turns out that this evaluation kit is in PCI plug-in board format
(clearly intended
to run in a desktop PC), and has the following stackup:

TOP
GND
SIG1
GND
PWR
PWR
GND
SIG2
GND
BOT

This is of course a wonderful stackup for power distribution, but it
requires running
close to half of the signals on the outside layers, since there are only two
internal
signal layers.  The evaluation kit runs many of the DDR SDRAM, PCI, and GMII
traces on
the top and bottom layers.  Only clocks and HyperTransport traces seem to be
strictly
limited to SIG1 and SIG2.

My question is this:  Is this kind of layout likely to radiate significantly
into other
boards in the enclosure (relative to a board with more layers, having added
planes
outside all signal layers), thereby risking excessive CM currents from the
cables
leading from these other boards?  As I have mentioned, we have always
believed that it
would, and have avoided such a stackup. But I wonder if we've been going
overboard and
wasting money on extra layers.

Ken Hayden
Consulting Engineer
Integral Access



------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: