I don't recall a test that used Kodak Rapid Selenium Toner for fixing.
In the darkroom we used Kodak HT-2 Test for hypo retention. see
attachment.
In Photo Tech in Kodak Park there was also an automated test. The
methylene blue test gave a meausure of hypo retention per cm2.
I don't havea recollect
On Tuesday, February 16, 2021, 02:00:19 PM EST, `Richard Knoppow
<dickburk@xxxxxxxxxxxxx> wrote:
It seems to me that Kodak had an alternative test for degree
of fixing using KRST diluted (by memory)1:10 This was an
alternative to the sodium sulfide test and was supposed to be
more stable and give stains more like those in the Kodak chart.
Bob Shanebrook might remember or else I will see if I can find
the publication that had this.
On 2/16/2021 6:31 AM, Tim Daneliuk wrote:
On 2/16/21 6:51 AM, BOB KISS wrote:
DEAR ROBERT,
I got staining in the whites of my fiber based prints often
when I combined the Rapid Selenium Toner with the HCA. Never got it
following your sequence below.
CHEERS!
BOB
Bob -
This was also my experience. I have read that KRST will stain if a
print is underfixed.
=============================================================================================================
To unsubscribe from this list, go to www.freelists.org and logon to your
account (the same e-mail address and password you set-up when you
subscribed,) and unsubscribe from there.