RE: Restart files in AutoUpgrade.

  • From: "Fadi Hasweh" <fhasweh@xxxxxxxxxx>
  • To: <ora-apps-dba@xxxxxxxxxxxxx>
  • Date: Tue, 27 Jun 2006 16:22:01 +0300

Are you sure you chose the hidden option 8 it should work, its an hidden
option

-----Original Message-----
From: ora-apps-dba-bounce@xxxxxxxxxxxxx
[mailto:ora-apps-dba-bounce@xxxxxxxxxxxxx] On Behalf Of
francisco.martinez@xxxxxxxxxxxxxx
Sent: Tuesday, June 27, 2006 4:14 PM
To: ora-apps-dba@xxxxxxxxxxxxx
Subject: RE: Restart files in AutoUpgrade.

Thanks a lot Fadi for your quick response.

I choose that option saying this failing worker to quit, but
AutoUpgrade's
execution never got me to the shell prompt, it just stayed there ....

I tried a lot of options inside of adctrl's menu, but AutoUpgrade
execution screen never came back to the shell prompt.

Thanks in advance.

Kind regards,

Francisco Mtz.


> Try to run adctrl then chose option 8 type all, then try to run the
> adutoupgrade
>
> -----Original Message-----
> From: ora-apps-dba-bounce@xxxxxxxxxxxxx
> [mailto:ora-apps-dba-bounce@xxxxxxxxxxxxx] On Behalf Of
> francisco.martinez@xxxxxxxxxxxxxx
> Sent: Tuesday, June 27, 2006 4:01 PM
> To: ora-apps-dba@xxxxxxxxxxxxx
> Subject: Restart files in AutoUpgrade.
>
> Hi partners,
>
> Yesterday I had an issue and I couldn't continue with an AutoUpgrade
> execution.
>
> Unfortunately I received a lot of problems during AutoUpgrade's
> execution
> due "INVALID" packages, and the last job finished with "FAILED"
status,
> so
> I couldn't continue with this process.
>
> Looking at Metalink the solution was to set next events in my init
file:
>
> event="10932 trace name context level 32768"
> event="10933 trace name context level 512"
> event="10943 trace name context level 16384"
>
> I tried to cancel my AutoUpgrade execution, saying to the "FAILED"
> worker
> to quit, but it never exit, so I decided to kill my "AutoUpgrade"
> process.
>
> After defining the above events I bounced my database, but I couldn't
> continue with my last AutoUpgrade's process execution, the problem was
> that restarted files couldn't be read.
>
> Fortunately it was only a test, but I would like to know which could
be
> the procedure to continue with my last AutoUpgrade execution?, what is
> the
> correct way to follow in case I want to restart AutoUpgrade's process?
>
> Any advice or help will be really appreciated.
>
> Thanks in advance.
>
> Francisco Mtz.
>
>
> "This email is intended for the above named adressee (s) only and may
> contain confidential and/or privilege information and should not be
used
> by anyone who is not the original intended recipient(s). Any review,
> print, copy, reliance or distribution by others or forwarding without
> express permission is strictly prohibited  If you have received this
email
> in error, kindly notify the sender immediately by reply email and
delete
> this email and any attachments from your mailbox or any other storage
> mechanism. Thank you.
> Email transmission cannot be guaranteed to be secured or error free,
as
> information could be intercepted, corrupted, lost, destroyed, received
> late or incomplete, or could contain viruses. The sender therefore
does
> not accept liability for any error or omission in the contents of this
> message, which arises as a result of email transmission. Opinions,
> conclusions and other information in this message that do not relate
to
> the official business of Umniah Mobile Company and is not its
> responsibility shall be understood as neither given nor endorsed by
the
> organization."
>
>



"This email is intended for the above named adressee (s) only and may contain 
confidential and/or privilege information and should not be used by anyone who 
is not the original intended recipient(s). Any review, print, copy, reliance or 
distribution by others or forwarding without express permission is strictly 
prohibited  If you have received this email in error, kindly notify the sender 
immediately by reply email and delete this email and any attachments from your 
mailbox or any other storage mechanism. Thank you.
Email transmission cannot be guaranteed to be secured or error free, as 
information could be intercepted, corrupted, lost, destroyed, received late or 
incomplete, or could contain viruses. The sender therefore does not accept 
liability for any error or omission in the contents of this message, which 
arises as a result of email transmission. Opinions, conclusions and other 
information in this message that do not relate to the official business of 
Umniah Mobile Company and is not its responsibility shall be understood as 
neither given nor endorsed by the organization."


Other related posts: