[argyllcms] Re: Calibrating a digital photo frame

  • From: "Frédéric Mantegazza" <frederic.mantegazza@xxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Fri, 14 Dec 2007 11:09:18 +0100 (CET)

Le 14/12/2007, "Graeme Gill" <graeme@xxxxxxxxxxxxx> a écrit:

>> Ok. But then, how do I reconstruct a .ti3 file from all spotread measures
>> of these patches?
>
>If you run spotread with a logfile argument, it will save
>each reading. You'll have to convert the .ti1 or .ti2 file
>to a .ti3 manually though, by stitching the CIE readings
>back together with the device value.

Thanks!

>(Hacking the code to send a raster file automatically
>might be easier in the long run)

I agree. Do you think it could be implemented as a hook in Argyll? I
think of adding an optional argument taking the script as param, giving
to it some usefull internal values...

--
   Frédéric