I have been working on ONE Rca 169 for what seems like TEN years,! wish I could find a bad cap (or something) have received informatiuon from every (I do mean EVERY) body on the list nothing seems to help find the prob!from Dan Mundy the complete print of all suspect circuit,s read them metered them all voltages within ...from Tech lind- suggestion to chang plugs -no..from Clint to check items (all voltages on the pin outputcorrectso.........)I want to stand this projo up against the wall and shoot it but .... the customer thinks it,s my fault.it came in dead, had the 169mod rebuilt, then trippler shorted befor i could look at the raster. wasited a Looonnnnnnnng time for the trippler, and now this .pinchusion bowed top and bottom(c4402 did not cure thanks dennis enyway)also some parabolic distortion on both sides....enybody seen this? PTV adapter also rebuilt all voltages on D-conv,with specsnot a yoke prob because each gun has the almost same distortion.I don,t want to rant on (will put someone to sleep)BUT.........Sanford On Tue, 27 Nov 2001 20:47:38 -0600 Bill Grabowski <bgrabowski@xxxxxxxxx> writes: > > I've been working on CTC169's for ten years but I never found a > leaky > cap that I > can think of...... > > Bill Grabowski > Triangle Appliance > > > "Leonard G. Caillouet" wrote: > > > > I am wondering if you all have seen many leaky caps in these sets. > I just > > did two this week that had leaky Nichicon 105 degree caps. The > electrolyte > > caused enough corrosion to damage a couple of traces. These are > the first I > > have seen like this and am wondering if we can expect this to be > as common > > as in the Hitachi and Misubishi projection sets. How far do you > guys go in > > looking for other caps going bad on these sets. I have found that > sometimes > > the only way that you can find them is to heat the pins and see if > they > > smell or remove them and visually inspect them. Many of the ones > that are > > starting to leak check OK on all four tests, capacitance, ESR, DA, > & leakage > > current. Should we be checking all of them on these sets? > > > > Leon. > > > > Leonard G. Caillouet > > Service Manager > > Electronics World > > Gainesville, FL > > 352-332-5608 > > 352-332-5668 (fax) > > > > ================================= > > Help make your TechAssist database better! > > Submit your fixes here: > http://circuitwork.com/techassist/tip/#tips > > ================================= > > To UNSUBSCRIBE your email address, click here: > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > ================================= > Help make your TechAssist database better! > Submit your fixes here: http://circuitwork.com/techassist/tip/#tips > ================================= > To UNSUBSCRIBE your email address, click here: > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > ================================= Help make your TechAssist database better! Submit your fixes here: http://circuitwork.com/techassist/tip/#tips ================================= To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe