When checking diodes for leakage, what range on the ohm meter do you use and is 
there an acceptable amount?  Sounds like electronics 101 but I have a couple of 
diodes that are flat case diodes mounted on a heat sink. They read 160  front 
to back on the diode check. No reading back to front. However they read 20k on 
the ohms scale. If heated this reading goes down to 2 or 3 K. I normally set my 
meter on 100k ohm for leakage. I thought they must be leaking. But wondered if 
there are some big diodes that test this way normally? Someone said that 10X 
the back to front was normal. These are in the secondary of a SMPS + & --  25v 
to convergence amps. 