Hello SI-LISTers, Thanks to all of you who replied to my post. A number of questions have been raised and I wish to answer them. 1) I used HP 2.5 GHz probes with HP Infinium 1.5 GHz oscilloscope, using 8 GHz sampling rate. 2) I had gone through several Application Notes/other material and decided to use source terminations because of the following constraints: a) I do not have enough board space to provide parallel terminations or both. b) I am already exceeding our power budget, and can't afford the additional current drain of parallel terminations. c) The parallel termination used by me (on the failing bits only) were selected by simulations and were also found to work on the actual card. The problem as I see is that brand "X" DRAM puts data after the Strobe (although still within their specs of 500 ps), whereas brand "Y" DRAM puts data before the Strobe. Hence, I have a problem of matching my card layout to work with both DRAMs. Regards, Ravinder PCB Development and Design Department IBM Corporation Email: ajmani@xxxxxxxxxx *************************************************************************** Always do right. This will gratify some people and astonish the rest. .... Mark Twain ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu