[ibis-macro] Re: IBIS-to-AMS script update

  • From: "Paul Fernando" <prfernan@xxxxxxxx>
  • To: ibis-macro@xxxxxxxxxxxxx
  • Date: Wed, 8 Feb 2006 16:57:08 -0500 (EST)

The updated version is attached.
1) Fixed
2) Modified to only one define (verilog)
3) The VHDL file already had blank lines between tables. In Verilog, can I have 
empty
lines in between or do I need "\" on these empty lines? This version has "\"s 
to be on
the safe side.

The [... reference] and rise/fall waveform order issues are also fixed.

Thanks,
Paul

On Wed, February 8, 2006 2:51 pm, Paul Fernando wrote:
> Arpad,
> They are all minor changes.
> I'll have them fixed before the end of the day.
> Thanks,
> Paul
>
> On Wed, February 8, 2006 2:11 pm, Muranyi, Arpad wrote:
>> Paul,
>>
>> I tried the Verilog portion of your script today
>> and found a couple of minor things.
>>
>> 1)  When the IBIS file doesn't have something,
>> don't print it out in the .dat file.  For example,
>> in a 3-state buffer there are no Vinh and Vinl
>> parameters, yet you printed them in the .dat
>> file with zero values.  This may apply to all
>> other parameters, and the VHDL portion too, but
>> I didn't test it.  The only exception to this
>> rule would be the voltage reference parameters,
>> which I discussed in an earlier reply.
>>
>> 2)  You printed three `define statements in the
>> .dat file.  While it can be done that way also,
>> I would prefer just to use one at the beginning.
>> If we have multiple definitions, the netlist will
>> have to use the same number of calls in the
>> parameter passing section, and that will begin
>> to look too busy.  The whole point of doing it
>> with this .dat file and macro definition was to
>> reduce the amount of typing on the netlist.
>>
>> 3)  Cosmetics:  You could put an extra "blank"
>> line between the various IV and Vt tables to make
>> it somewhat easier to read (in case someone needs
>> to look at it with an editor).
>>
>> I didn't see a response from you to the suggestions
>> I made on the voltage reference parameters and the
>> association of the waveforms with r1, r2, f1, f2.
>> Do you think you can implement it?
>>
>> Thanks,
>>
>> Arpad
>> =================================================---------------------------------------------------------------------
>> IBIS Macro website:  http://www.sisoft.com/ibis-macro
>> IBIS Macro archives: //www.freelists.org/archives/ibis-macro
>> To unsubscribe send an email:
>>   To: ibis-macro-request@xxxxxxxxxxxxx
>>   Subject: unsubscribe
>>
>>
>
>
> ---------------------------------------------------------------------
> IBIS Macro website:  http://www.sisoft.com/ibis-macro
> IBIS Macro archives: //www.freelists.org/archives/ibis-macro
> To unsubscribe send an email:
>   To: ibis-macro-request@xxxxxxxxxxxxx
>   Subject: unsubscribe
>
>

Other related posts: