Hi Guys, this Zenith RZ56Z83D8 shuts down the tubes on bright scenes/scene change, original complaint was dead, changed 9-1674 module, convergence module 9-1690 failed 20 minutes after installing 9-1674, replaced STK`s, had no 16 v line, found open winding on flyback, replaced fly, now G2 is too high, turn control all the way counterclockwise red & green still lit, set jumpers to disable, turned up each tube to retrace and then back down to extinguish retrace, replaced jumpers to normal mode and tubes come on very bright, and instantly go out, set has a good picture when it`s running but obviously X-Ray protect is shutting the tubes off, any ideas or should I buy another 9-1674? Needless to say customer is very pissed off at this point, your help is appreciated, Larry E Larry Eastman American TV & Electronics Crystal River, Fl. 34428 ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/