Hi folks: I am having problems with the following set. Zenith Model # A25B33W, Chassis# 9-2002 This set came in dead. I can hear the relay click but the set does not come on. if I hold the power button in I can hear the clicking. Hot checks good and has 128.1V on the collector. The 48volt regulator( STR 53041) has 48.3V out. I have checked the diodes around the flyback and they seem to be ok. Likewise with the surrounding caps, they check ok with the ESR meter. I am going out to by the SAMS but wanted to check and see if you guys have had similar problems with this set. Thanks Rich Richard J. Bateman, CET, CA. Electronics Program Area Coordinator Amherst Campus 716-691-0012 EXT - 232 E-MAIL rjbateman@xxxxxxxxxxxxxxxxxx ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html To CHANGE your email address, click here: http://www.techassist.net/forms/change.html ------------------------------------------ ***NEW*** Tips Added Instantly!!!*** Submit Repair Tips here: http://www.tech-assist.org/secure/tip/