Check your 200volt B+ usually a 4.7M to 10M 250volts. Bill Grabowski Triangle Appliance Kenosha, WI 53142 Bruce Tiedeman wrote: > Black screen in 3" on left of picture. It looks like a bad cap, but have > checked and changed many. The picture looks good except for this. It does > not look like a horizontal problem. There is no distinct line where it is in > from the side, the black kind of bleeds in . The regulation and horizontal > pulse looks very clean. > If I vary the screen VR control on CRT board it does affect the black area > some .. I don't think this set uses the IK circuit like some. I don't have a > print to check the video circuit. I am hoping some one that works on a lot > of Sony's has seen this before. I ESR'd most caps, used heat on the caps > and cold spray but do not see a change in the condition. The picture > condition stays the same hot or cold. > thanks > Bruce. > > B&T Electronics > 139 Margaret St > Sarnia Ontario > Canada > N7T 2Y3 > 519 344 1850 > > > ----------------------------------------------------------------------------- > This Email List is Public. Remove: http://www.tech-assist.org/remove.htm > Lost Password: http://www.tech-assist.org and select "Login Problems?". > Email Archives: //www.freelists.org/archives/techassist/ > -- ***************************** Bill Grabowski Triangle Appliance Kenosha,Wi 53142 262-694-6500 262-694-6523 fax bgrabowski@xxxxxxxxx ***************************** ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/