Hi All
What's the standard way to convert drive strength in mA to a equivalent
Capacitive load. For example if i want to convert 8mA to equivalent pF
load, what's the most reasonable calculation.

Apparently considering full voltage swing in C(dv/dt) equation gives
pessimistic results.
what's the typical dt should be considered.