From: DarkroomMagic <info@xxxxxxxxxxxxxxxx> Subject: [pure-silver] Re: Strorage life of diluted fixer? Date: Wed, 22 Sep 2004 18:07:38 +0200 > It works well and the fixer shelf life is increased at higher > concentrations. This is not the case. Dilute, working strength fixer is more stable than concentrate. > I print every week, but never had fixer go bad on me. It's exhausted > (1 g/l) before it goes bad. What's your assay method to get quantitative silver concentration? -- Ryuji Suzuki "Keep a good head and always carry a light camera." ============================================================================================================= To unsubscribe from this list, go to www.freelists.org and logon to your account (the same e-mail address and password you set-up when you subscribed,) and unsubscribe from there.