Re: ORA-600 after July PSU apply -- production down.

  • From: "Powell, Mark" <mark.powell2@xxxxxxx>
  • To: "oracle-l@xxxxxxxxxxxxx" <oracle-l@xxxxxxxxxxxxx>
  • Date: Thu, 24 Aug 2017 15:53:50 +0000

I could not find a hit a support for the ORA-00600 but did find this which 
might or might not be of any help


JULY PSU 2017 PATCH Fails to apply "Conflict with 19285025" (Doc ID 2291644.1)


Mark Powell
Database Administration
(313) 592-5148


________________________________
From: De DBA <dedba@xxxxxxxxxx>
Sent: Thursday, August 24, 2017 11:32:35 AM
To: Powell, Mark; oracle-l@xxxxxxxxxxxxx
Subject: Re: ORA-600 after July PSU apply -- production down.


 Even starting in nomount mode gives ORA-600.


I just attempted to create a dummy instance with a init.ora file with only 1 
line in it (db_name = ORCL) - no ASM, no spfile in play. Starting that also 
failed with the same ORA-600 [kgfmGetCtx0].


Cheers,

Tony

On 25/08/17 01:11, Powell, Mark wrote:

ORA-01078: failure in processing system parameters <<


Have you in fact verified that your spfile parameters are in fact valid?  
Startup nomount and full the spfile into a pfile then review it carefully.



Mark Powell
Database Administration
(313) 592-5148


________________________________
From: oracle-l-bounce@xxxxxxxxxxxxx<mailto:oracle-l-bounce@xxxxxxxxxxxxx
<oracle-l-bounce@xxxxxxxxxxxxx><mailto:oracle-l-bounce@xxxxxxxxxxxxx> on behalf 
of De DBA <dedba@xxxxxxxxxx><mailto:dedba@xxxxxxxxxx>
Sent: Thursday, August 24, 2017 10:51:24 AM
To: oracle-l@xxxxxxxxxxxxx<mailto:oracle-l@xxxxxxxxxxxxx>
Subject: ORA-600 after July PSU apply -- production down.

HI,
I've tonight applied the July PSU to the last environment - production. All 
other environments, including DR, went swimmingly, but after applying the 
patches when I tried to startup upgrade to apply the in-database part, I was 
regaled with the following fine errors on both nodes:
00:28:52 [25-AUG-17][SYS@MyProd]$ startup upgrade
ORA-01078: failure in processing system parameters
ORA-00600: internal error code, arguments: [kgfmGetCtx0], [kgfm.c], [2840], 
[ctx], [], [], [], [], [], [], [], []
The parameter files of course do still exist. The MOS lookup tool has no 
information and my 24/7 db is down. Any clues?

I've already attempted to roll-back the OCW part, but that had no effect. 
Although now opatch lsinventory no longer lists the original version of that 
patch (11.2.0.4.5) either.

Environment:
ODA X4-2
RDBMS 11.2.0.4
ASM 12.1.0.2
Database PSU 11.2.0.4.170718
OCW PSU - no longer shown
OVJM PSU 11.2.0.4.170718
Thanks,
Tony

Other related posts: