Even starting in nomount mode gives ORA-600.
I just attempted to create a dummy instance with a init.ora file with only 1
line in it (db_name = ORCL) - no ASM, no spfile in play. Starting that also
failed with the same ORA-600 [kgfmGetCtx0].
Cheers,
Tony
On 25/08/17 01:11, Powell, Mark wrote:
>> ORA-01078: failure in processing system parameters <<
Have you in fact verified that your spfile parameters are in fact valid?
Startup nomount and full the spfile into a pfile then review it carefully.
Mark Powell
Database Administration
(313) 592-5148
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
*From:* oracle-l-bounce@xxxxxxxxxxxxx <oracle-l-bounce@xxxxxxxxxxxxx> on behalf of De
DBA <dedba@xxxxxxxxxx>
*Sent:* Thursday, August 24, 2017 10:51:24 AM
*To:* oracle-l@xxxxxxxxxxxxx
*Subject:* ORA-600 after July PSU apply -- production down.
HI,
I've tonight applied the July PSU to the last environment - production. All
other environments, including DR, went swimmingly, but after applying the
patches when I tried to startup upgrade to apply the in-database part, I was
regaled with the following fine errors on both nodes:
00:28:52 [25-AUG-17][SYS@MyProd]$ startup upgrade
ORA-01078: failure in processing system parameters
ORA-00600: internal error code, arguments: [kgfmGetCtx0], [kgfm.c], [2840],
[ctx], [], [], [], [], [], [], [], []
The parameter files of course do still exist. The MOS lookup tool has no
information and my 24/7 db is down. Any clues?
I've already attempted to roll-back the OCW part, but that had no effect.
Although now opatch lsinventory no longer lists the original version of that
patch (11.2.0.4.5) either.
Environment:
ODA X4-2
RDBMS 11.2.0.4
ASM 12.1.0.2
Database PSU 11.2.0.4.170718
OCW PSU - no longer shown
OVJM PSU 11.2.0.4.170718
Thanks,
Tony