RE: ORA-600 after July PSU apply -- production down.

  • From: Noveljic Nenad <nenad.noveljic@xxxxxxxxxxx>
  • To: "'dedba@xxxxxxxxxx'" <dedba@xxxxxxxxxx>, "mark.powell2@xxxxxxx" <mark.powell2@xxxxxxx>, "oracle-l@xxxxxxxxxxxxx" <oracle-l@xxxxxxxxxxxxx>
  • Date: Thu, 24 Aug 2017 15:43:47 +0000

Please apologize my the trivial suggestion, but could you double check that 
correct init/spfile is being picked (correct directory, no typo in file name). 
Verify also with show parameter file in sqlplus which file is used.

From: oracle-l-bounce@xxxxxxxxxxxxx [mailto:oracle-l-bounce@xxxxxxxxxxxxx] On ;
Behalf Of De DBA
Sent: Donnerstag, 24. August 2017 17:33
To: mark.powell2@xxxxxxx; oracle-l@xxxxxxxxxxxxx
Subject: Re: ORA-600 after July PSU apply -- production down.


 Even starting in nomount mode gives ORA-600.



I just attempted to create a dummy instance with a init.ora file with only 1 
line in it (db_name = ORCL) - no ASM, no spfile in play. Starting that also 
failed with the same ORA-600 [kgfmGetCtx0].



Cheers,

Tony

On 25/08/17 01:11, Powell, Mark wrote:

ORA-01078: failure in processing system parameters <<



Have you in fact verified that your spfile parameters are in fact valid?  
Startup nomount and full the spfile into a pfile then review it carefully.




Mark Powell
Database Administration
(313) 592-5148


________________________________
From: oracle-l-bounce@xxxxxxxxxxxxx<mailto:oracle-l-bounce@xxxxxxxxxxxxx
<oracle-l-bounce@xxxxxxxxxxxxx><mailto:oracle-l-bounce@xxxxxxxxxxxxx> on behalf 
of De DBA <dedba@xxxxxxxxxx><mailto:dedba@xxxxxxxxxx>
Sent: Thursday, August 24, 2017 10:51:24 AM
To: oracle-l@xxxxxxxxxxxxx<mailto:oracle-l@xxxxxxxxxxxxx>
Subject: ORA-600 after July PSU apply -- production down.

HI,
I've tonight applied the July PSU to the last environment - production. All 
other environments, including DR, went swimmingly, but after applying the 
patches when I tried to startup upgrade to apply the in-database part, I was 
regaled with the following fine errors on both nodes:
00:28:52 [25-AUG-17][SYS@MyProd]$ startup upgrade
ORA-01078: failure in processing system parameters
ORA-00600: internal error code, arguments: [kgfmGetCtx0], [kgfm.c], [2840], 
[ctx], [], [], [], [], [], [], [], []
The parameter files of course do still exist. The MOS lookup tool has no 
information and my 24/7 db is down. Any clues?

I've already attempted to roll-back the OCW part, but that had no effect. 
Although now opatch lsinventory no longer lists the original version of that 
patch (11.2.0.4.5) either.

Environment:
ODA X4-2
RDBMS 11.2.0.4
ASM 12.1.0.2
Database PSU 11.2.0.4.170718
OCW PSU - no longer shown
OVJM PSU 11.2.0.4.170718
Thanks,
Tony

____________________________________________________
Please consider the environment before printing this e-mail.
Bitte denken Sie an die Umwelt, bevor Sie dieses E-Mail drucken.

<html xmlns="http://www.w3.org/1999/xhtml";>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
<style type="text/css">p { font-family: Arial;font-size:9pt }</style>
</head>
<body>
<p>
<br>Important Notice</br>
<br>This message is intended only for the individual named. It may contain 
confidential or privileged information. If you are not the named addressee you 
should in particular not disseminate, distribute, modify or copy this e-mail. 
Please notify the sender immediately by e-mail, if you have received this 
message by mistake and delete it from your system.</br>
<br>E-mail transmission may not be secure or error-free as information could be 
intercepted, corrupted, lost, destroyed, arrive late or incomplete. Also 
processing of incoming e-mails cannot be guaranteed. All liability of the 
Vontobel Group and its affiliates for any damages resulting from e-mail use is 
excluded. You are advised that urgent and time sensitive messages should not be 
sent by e-mail and if verification is required please request a printed 
version.<br/>
</p>
</body>
</html>

Other related posts: