Elena wrote: > Unfortunately I still don't understand well if it's the case here or not. > Keep in mind that to test with thousands (3000-6000) samples I'm almost > forced to use measuring tricks, like printing smaller patches and longer > strips for my i1 (eg. printtarg -v -ii1 -a0.6 -A1.67 -C -m0 -P -L -p420x297 > will fit more than 3000 patches on a A3 paper feed horizontally). > It would be a long and crazy work otherwise, working with standard patches. > There's some risk of crosstalking ? Maybe. I've done several experiment with I1 Rev.D and the result are the next: The reading error with 8x8mm patches between differnet sheets is about 0.25-0.27dE2000. For 6x6mm patches is about 0.33, for 4x4mm patches error is about 0.5-0.57dE2000. I think there is very little crosstalk may be. The maximum crosstalk is about 0.08dE2000 on the glossy premium paper. I think smaller patches are not the source of trouble.