[argyllcms] Re: ArgyllCMS V1.8.0 Released

  • From: Graeme Gill <graeme@xxxxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Fri, 21 Aug 2015 12:23:52 +1000

Ben Goren wrote:

All I can easily find in the documentation about that is this:

An EMISINPUT is a camera with emissive reference data.

Any chance for a bit more detail?

Sorry, no. You already have all the information there is, since
it was added specifically for you. No ArgyllCMS tool creates
a file with this designation.

Graeme Gill wrote on 10th July 2015:
I've uploaded .... which
has code to support a .ti3 with a DEVICE_CLASS of EMISINPUT
that should treat the spectral values as self-luminous.

Graeme.