It sounds like your thread feed drive gear is cracked. Easy Fix, you can do it 
yourself. Take apart the upper clam shell covers behind the needle case. You 
will see a single white plastic drive gear. Laser Up Arrow will advance the 
threadfeed. You will be able to see the gear wobble in and out of engagement 
from the threadfeed assembly. You will need a precision small pliers for 
retaining clips in order to get it off.  When you order the gear make sure you 
also order a couple spare clips, you will loose and/or bend them. Don't forget 
to grease the inside of the gear with Polymer.  To get the gear out you can 
either order a Fixture (Recommmended) or you can remove the circuit board 
directly above the gear. If you choose to remove the circuit board make sure 
you mark exactly where the board is before you remove it. The board can be 
adjusted front to back to center the drive gear to the thread feed assembly. 
Good Luck !!!