check your 5 volt line if lower than 4.8 volts may have erratic shutdown/startup problems. usually a 5.6volt zener changes value. check all solder connections carefully around hor drive transformer. Robert tvservice@xxxxxxxxxxxxx H & H Electronics Inc ----- Original Message ----- From: "larry" <schntv@xxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Tuesday, August 17, 2004 1:40 PM Subject: [TechAssist] RCA ctc169, 35 " intermittent dead > replaced 3 electrolytic at the smp IC. also the 15 V rectifier > and cap. > still goes off once a day. > then comes on after a few minutes > Any clues appreciated, > Larry > > -- > Schneider TV & Electronic Inc. > 5415 N. Wooster ave. > Dover, Ohio 44622 www.geocities.com/schntv2000/ > 330-343-0768 FCC. first class & Extra class K8WLY > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/