[TechAssist] Re: Proscan CTC169

  • From: Bill Grabowski <bgrabowski@xxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Thu, 30 Sep 2004 18:48:28 -0500

If your sure its not the Horiz the most common fix is the 2.2m/100vand 
15m/63v next to the regulator IC and either a 39m or 47m off of chopper.
And of cource the imfamous CR4118 on the secondary. Just change these 
four parts usually fixes 75% of CTC169 P.S.'s

Bill Grabowski
Triangle  Appliance
Kenosha, Wi  53142

Hoyt's TV wrote:
> Direct view CTC169
> 
> Power supply is not firing up. I cannot find any shorts or heavy loads on
> the output side.
> I've tried watching it on a scope and bringing the AC up slowly, not even a
> twitch.
> Has raw B+.
> I haven't had many CTC169s, does anyone know of any common failures in this
> supply?
> 
> Looks like a thousand or more tips in the tip section, will take me a month
> just to sort through them.
> 
> Thanks
> 
> Russ Hoyt
> Hoyt's TV
> Exeter, NH
> 
> 
> 
> 
> -----------------------------------------------------------------------------
> Lost Password:
> http://www.tech-assist.org  and select "Login Problems?".
> Email Archives:
> //www.freelists.org/archives/techassist/
> 
> 

-- 
*****************************
Bill Grabowski
Triangle Appliance
Kenosha,Wi 53142
262-694-6500
262-694-6523 fax
bgrabowski@xxxxxxxxx
*****************************

-----------------------------------------------------------------------------
Lost Password:
http://www.tech-assist.org  and select "Login Problems?".
Email Archives:
//www.freelists.org/archives/techassist/