Need Help; Set came in dead, found H/O shorted (Q502) and replaced. Replaced C431 (1uf/200volts) and C432 (100uf/200volts) Resoldered R504 and R525. Have 157 volts on main filter, but have no idea where my standby voltage is. I have no circuit for this, and do not do many Magnavox in this area. Have found a point marked start up voltage, but may not have correct reference to ground. (reads less than 1.2 volts) Have no relay click, and set is Still, basically DEAD. Any Magnavox "hot shot" that can point me in the right direction would be appreciated. Thanks; -Ed- Please Change the address in your Address Book Default. teltek2@xxxxxxxxxxxx Secondary........ teltek35@xxxxxxxxxxx Tel-Tek Electronics. ------------------------------------------ Make your TechAssist database better! Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ ------------------------------------------ To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe Or send a BLANK email with unsubscribe in the SUBJECT field to the address above.