Tayyab Jamil Qureshi, I have been successfull with these using 5 mil resolution. This allowed 3 traces between the BGA pads; also, I put a via on all BGA pads, hole was drilled 0.3mm thus getting about 0.2mm after plating. This leaves 0.508mm (20 mil) pad diameter - and allowed me to route the whole mess without sacrificing any area on two signal layers (and 4 planes). There is an important detail with the through-holes on every BGA pad. Sometimes some of the solder balls on the BGA package are not well attached; this may result into losing the ball during reflow (it just flows through the hole to form a bubble on the bottom of the board). My solution to that was to reflow all BGA packages with some flux once belly up; this makes sure all balls are really soldered to the package, and surface tension does the rest of the job during the final reflow (it does it for most of the balls either way, the thing is, we want all of them to connect :-). Good luck, Dimiter -------------------------------------------------------------------- Dimiter Popoff Transgalactic Instruments, Gourko Str. 25 b, 1000 Sofia, Bulgaria http://transgalactic.freeyellow.com ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http://www.si-list.org List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu