Joseph, It sounds like your Apps configuration is not 100% running on Virtual host. Your CM-s are running on physical host, is it right? If you might want to play with Parallel Concurrent Processing feature which allow you to run CM-s on several hosts at the same time. Or if you would like to keep those running on physical host then just before running postclone actions you need to execute fnd_conc_clone.setup_clean; procedure in order to clean old records in FND_NODES table. Postclone calls autoconfig which adds proper hostname to that table. If you CM-s have been interrupted in abort mode (shutting down a node for example) then you might considering to run cmclean.sql (available on Mentalink just enter script name in the search field) script just before starting up CM-s in the target node. Jurijs On 6/22/07, Joseph Amalraj <joseph@xxxxxxxxxxxxxx> wrote:
Hi, We have a EBS single node environment. This uses same virtual node for all services. A failover environment is currently configured so that the virtual node (and its ip address) fails over to the standby site. We ran preclone and rapid clone for the failover. All services came up except for concurrent manager processes. I guess I should have registered the physical host name through OAM as a post clone step. Please give me your input how this should be configured. Thanks Joseph Amalraj
-- Yury +371 29268222 (+2 GMT) ============================================ http://otn.oracle.com/ocm/jvelikanovs.html