[modeleng] Re: Boiler descaling

  • From: "alan stepney" <alan@xxxxxxxxxxxxxxxx>
  • To: <modeleng@xxxxxxxxxxxxx>
  • Date: Sun, 26 Feb 2006 01:57:25 -0000

Forwarded on behalf of Phill Smith.

-------------------------------------------

Barrie,

Hydrochloric acid is the best stuff to use for boiler descaleing. A weak 
solution is best. When the HCl reacts with the offending scale, it forms 
salts, which are highly soluble and easily washed out. The use of sulphuric 
acid will create sulphates, which are not particularly soluble, and 
therefore recoat the internal surfaces. Vinegar (if I could remember it's 
equation) is not much better than H2SO4, unless a scrubbing device is used.

Hydrochloric acid is available from swimming pool chemical suppliers, and is 
cheap.


Cheers,

Phill.