[AR] Re: Electric driven Turbo Pumps

  • From: Henry Spencer <hspencer@xxxxxxxxxxxxx>
  • To: arocket@xxxxxxxxxxxxx
  • Date: Thu, 15 Dec 2016 19:41:01 -0500 (EST)

On Thu, 15 Dec 2016, Pierce Nichols wrote:

The piston cylinder volume still needs to be filled from tank pressure, so
there's a relation there between tank pressure and maximum pump speed...

For a single cylinder, yes, but if you've got two or three of them operating in sync, you can maintain something approaching continuous flow in the feed line from the tank, so you're not *accelerating* a long slug of liquid every time, just diverting the flow back and forth.

This does add design complexity, of course.

Henry