I still think you are looking at some type of network latency problem and that reinstalling is not going to solve it. Are all of your servers hooked into a switch versus a hub? Are the ports locked to match the Nics? Are the Test servers hooked up to the same network segment? I'd be trying to figure out what is different about them that makes them work. Is it simply because there are less users on the box maybe for example. If the test farm works and they are the same boxes you can simply make an image of the test servers and restore it to the other ones and change the machine names and IP's. The advanced concepts guides give detailed info on cloning servers. JK -----Original Message----- From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx]On Behalf Of Dan Samaan Sent: Thursday, September 26, 2002 10:00 AM To: thin@xxxxxxxxxxxxx Subject: [THIN] Re: Need to rebuild XPa Farm Cool thanks. I give it a try. And do you agree with my approach on the method I'm using on rebuilding the farm? Daniel J. Samaan=20 Senior Network/Security Engineer - CCSE, CCA, CCNA, MCSE dsamaan@xxxxxxxxxxxxxxxx -----Original Message----- From: Jim Kenzig [mailto:jimkenz@xxxxxxxxxxxxxx]=20 Sent: Thursday, September 26, 2002 8:53 AM To: thin@xxxxxxxxxxxxx Subject: [THIN] Re: Need to rebuild XPa Farm You can make an ICA file run the app seamless by adding the following lines to it at the end of the file. If the app is already published seamless they should be there when you create the ica file already. DesiredWinType=3D8 TWIMode=3DOn JK -----Original Message----- From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx]On Behalf Of Dan Samaan Sent: Thursday, September 26, 2002 9:45 AM To: thin@xxxxxxxxxxxxx Subject: [THIN] Re: Need to rebuild XPa Farm True, but using Seamless Published Apps is what I want them to use. Daniel J. Samaan=3D20 Senior Network/Security Engineer - CCSE, CCA, CCNA, MCSE dsamaan@xxxxxxxxxxxxxxxx -----Original Message----- From: Jim Kenzig [mailto:jimkenz@xxxxxxxxxxxxxx]=3D20 Sent: Thursday, September 26, 2002 8:43 AM To: thin@xxxxxxxxxxxxx Subject: [THIN] Re: Need to rebuild XPa Farm You do not need to visit every desktop. All you need to do is push a configured ICA file out to their desktop via a logon script to get them to go to the new server. You can create an ICA file by right clicking on the published app in the CMC and then copy the ICA file out to the users Desktop via a logon script. Or if you allow your users to save items put the ica file on a web page and instruct your users to right click on it and save it to their desktop. =3D20 Regards, Jim Kenzig http://thethin.net ********************************************** This weeks sponsor Kevsoft Corporation TScale by Kevsoft Corporation Support 30% to 40% more users on your server farm without buying new hardware! http://www.kevsoft.com/ *********************************************** For Archives, to Unsubscribe, Subscribe or set Digest or Vacation mode use the below link. http://thethin.net/citrixlist.cfm