[THIN] Re: Need to rebuild XPa Farm

  • From: Jim Kenzig <jimkenz@xxxxxxxxxxxxxx>
  • To: thin@xxxxxxxxxxxxx
  • Date: Thu, 26 Sep 2002 10:41:44 -0400

I still think you are looking at some type of network latency problem and
that reinstalling is not going to solve it.
Are all of your servers hooked into a switch versus a hub?  Are the ports
locked to match the Nics?  

Are the Test servers hooked up to the same network segment? I'd be trying to
figure out what is different about them that makes them work. Is it simply
because there are less users on the box maybe for example. 

If the test farm works and they are the same boxes you can simply make an
image of the test servers and restore it to the other ones and change the
machine names and IP's.  The advanced concepts guides give detailed info on
cloning servers.

JK

-----Original Message-----
From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx]On
Behalf Of Dan Samaan
Sent: Thursday, September 26, 2002 10:00 AM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: Need to rebuild XPa Farm



Cool thanks.  I give it a try.

And do you agree with my approach on the method I'm using on rebuilding
the farm?

Daniel J. Samaan=20
Senior Network/Security Engineer - CCSE, CCA, CCNA, MCSE
dsamaan@xxxxxxxxxxxxxxxx
-----Original Message-----
From: Jim Kenzig [mailto:jimkenz@xxxxxxxxxxxxxx]=20
Sent: Thursday, September 26, 2002 8:53 AM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: Need to rebuild XPa Farm


You can make an ICA file run the app seamless by adding the following
lines
to it at the end of the file. If the app is already published seamless
they
should be there when you create the ica file already.

DesiredWinType=3D8
TWIMode=3DOn

JK

-----Original Message-----
From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx]On
Behalf Of Dan Samaan
Sent: Thursday, September 26, 2002 9:45 AM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: Need to rebuild XPa Farm



True, but using Seamless Published Apps is what I want them to use.

Daniel J. Samaan=3D20
Senior Network/Security Engineer - CCSE, CCA, CCNA, MCSE
dsamaan@xxxxxxxxxxxxxxxx
-----Original Message-----
From: Jim Kenzig [mailto:jimkenz@xxxxxxxxxxxxxx]=3D20
Sent: Thursday, September 26, 2002 8:43 AM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: Need to rebuild XPa Farm


You do not need to visit every desktop.  All you need to do is push a
configured ICA file out to their desktop via a logon script to get them
to
go to the new server. You can create an ICA file by right clicking on
the
published app in the CMC and then copy the ICA file out to the users
Desktop
via a logon script.

Or if you allow your users to save items put the ica file on a web page
and
instruct your users to right click on it and save it to their desktop.
=3D20

Regards,
Jim Kenzig
http://thethin.net

**********************************************
This weeks sponsor Kevsoft Corporation 
TScale by Kevsoft Corporation 
Support 30% to 40% more users on your server farm
without buying new hardware!  
http://www.kevsoft.com/
***********************************************

For Archives, to Unsubscribe, Subscribe or 
set Digest or Vacation mode use the below link.

http://thethin.net/citrixlist.cfm

Other related posts: