[TechAssist] Re: WHAT MODEL OR CHASSIS?

  • From: mebonnell@xxxxxxxxx (Old TV Man)
  • To: techassist@xxxxxxxxxxxxx
  • Date: Wed, 6 Apr 2005 21:09:39 -0500

If you haven't done it yet sign up for chat@xxxxxxxxxxxxxxxx

What a thread this has turned into.

Max Bonnell
Bonnell TV
Robinson, IL 
 
Sender: techassist-bounce@xxxxxxxxxxxxx From: ampm@xxxxxxx(al=A0m) Date:
Wed, Apr 6, 2005, 10:01pm (CDT+1) To: techassist@xxxxxxxxxxxxx Subject:
[TechAssist] Re: [TechAssist]WHAT MODEL OR CHASSIS? Re: intermittent rca
Reply=A0to: techassist@xxxxxxxxxxxxx 

For a frikin dollar we have all this controversy???? Al Marquardt 

ampm@xxxxxxx
Al Marquardt Electronic Repair
206 W Main
Girardville Pa. 17935


----- Original Message ----- 
From: "Larry E" <videotech@xxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Wednesday, April 06, 2005 9:40 PM
Subject: [TechAssist] Re: [TechAssist]WHAT MODEL OR CHASSIS? Re: 
intermittent rca 

Damon, and if it fails ten days after you return the set you have a
pissed off 
customer who doesn`t believe you when you tell him it`s a different
problem, 
"set was dead when you picked it up, set is dead again" you didn`t fix
it right. 
How many times have we heard that one from a customer????? Makes more
sense to replace it the first time around and keep a customer then to
lose that customer doesn`t it ? Just my 2 cents, Larry E 
Larry Eastman
American TV & Electronics
Crystal River, Fl. 34428

----- Original Message ----- 
From: "Damon" <damon101@xxxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Wednesday, April 06, 2005 8:43 PM
Subject: [TechAssist] Re: [TechAssist]WHAT MODEL OR CHASSIS? Re: 
intermittent rca 

Why NOT replace it,to avoid Returns ??? 

- Peggs 
Because by measuring the actual voltage on the diode, I can get a 2nd
repair about 9 - 12 months later, out of warranty. Orrrrrr I can replace
it now and avoid that callback......just depends on the actual voltage I
see on my meter.....if it's 13 Volts or higher I don't touch it. 
You know, that's like taking your car in for a radiator repair and the
guy 
there throws in a battery because he knows it's going to fail.....and
charges you for it..... 

Damon Brunger
Telrad Electronics
Fort Wayne IN

----- Original Message ----- 
From: "peggs" <peggs@xxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>; <techassist@xxxxxxxxxxxxx>
Sent: Wednesday, April 06, 2005 10:45 AM
Subject: [TechAssist] Re: [TechAssist]WHAT MODEL OR CHASSIS? Re: 
intermittent rca 

It's a $1 part.
It fails frequently.
Why NOT replace it,to avoid Returns ??? 

Peggs 

At 06:02 AM 4/6/05, J. Knoll wrote: 
I was doing that but after a few returns a month later after the
original repair I started replacing that diode automatically to avoid
wasting time with returns. I hate the 169 and the less time on the bench
with one the better. 
Jay-Jays tv 

On Apr 6, 2005 8:36 AM, Damon <damon101@xxxxxxxxxxxxxx> wrote: 

Actually I monitor CR4118's voltage to determine whether it needs
replaced or not. 
14 volts -OK 
12 Volts - Replace 
10 Volts - Bad 
and there's a big wide replace area with skinny -OK / Bad sections if 
you 
want to make a meter out of it....;-) 
Yes replacing CR4118 will cover a multitude of 
problems/intermittants. 

Damon Brunger
Telrad Electronics
Fort Wayne IN

----- Original Message ----- 
From: "Electric Medic" <info@xxxxxxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Tuesday, April 05, 2005 11:58 PM
Subject: [TechAssist] Re: [TechAssist]WHAT MODEL OR CHASSIS? Re: 
intermittent rca 

Please put Make, Model (or Chassis), and Problem in subject line. Then 
email 
can be filed Automatically, Thanks. CR4118 should go without saying. 
Of 
course it will fix intermittent operation. That is the first part we 
change 
on all CTC169's regardless of customers problem. I would think all 
shops 
would change this on all CTC169 repairs, we do, don't we? 

Perry Bower
Electric Medic
"It's Cheaper to Keep Her"
http://www.electricmedic.com
3850 Washington Road Suite 4C
Martinez, Georgia 30907 
Phone: 706-8MEDIC4 (863-3424)
Phone: 706-863-3474
Fax: 706-863-2316 
mailto:info@xxxxxxxxxxxxxxxxx 

-----Original Message----- 
From: techassist-bounce@xxxxxxxxxxxxx 
[mailto:techassist-bounce@xxxxxxxxxxxxx]On Behalf Of Gary McCartney
Sent: Wednesday, April 06, 2005 12:48 AM To: techassist@xxxxxxxxxxxxx
Subject: [TechAssist] Re: intermittant rca 

Don't know if this will cure it but it has been recommended by many
techs to replace CR4118 (RCA # 164590 or FR302 generic)in every CTC169
that comes into the shop, whether it appears to be OK or not. This 
diode 
causes a lot of strange symptoms. 

Gary McCartney 
McCartney Electronics
Guelph Ontario Canada
Est. 1984 
email: gary (at) number63.ca 

GRAYSTV@xxxxxxx wrote: 
we have a 35 " rca ctc169BG5 that shuts down very intermitantly. 
like 
once 
a day. I measured the b+ after it shutdown and it did not waver. 
when 
it 
tried to turn on.otherwise i can't get a test. i have replaced
c4102,c4108,c4104,c612,cr4401,c4406,cr4402, c4403, and c4404. does 
anyone 
have any advice?? 

GraysTV/Glenn Gray
Berlin Ht's.OH 44814
Phone (419) 588-2325
graystv@xxxxxxx 
---------------------------------------------- 
--- 

-----------------------------------------------------------------------------
This Email List is Public. Remove: http://www.tech-assist.org/remove.htm
Lost Password: http://www.tech-assist.org  and select "Login Problems?".
Email Archives: //www.freelists.org/archives/techassist/

Other related posts: