[TechAssist] Re: RCA VCR Model VR480 - ejects tape

  • From: "J Silverman" <greentron@xxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Tue, 9 Mar 2004 15:32:46 -0500

Sounds like the thermal fuse inside the gear shift solenoid is open. The
solenoid can be seen from the top on the right side of the take-up reel.
Should measure about 18 ohms if OK. If it is OK the solenoid lever return
spring could be off or missing. Solenoid problems are usually caused by mode
switch/ mechanical alignment problems.
Jerry Silverman
Greentron Inc
4 Newland Ave
Greenville SC 29609
864 232 3889
Fax 271 2080
mailto:greentron@xxxxxxx
----- Original Message -----
From: "Wally Heise" <sirepair@xxxxxxxxxx>
To: "Tech Assist" <techassist@xxxxxxxxxxxxx>
Sent: Monday, March 08, 2004 11:02 PM
Subject: [TechAssist] RCA VCR Model VR480 - ejects tape


> I have a customer that wants this older vcr fixed.  Originally came in
with
> bad power supply, I fixed that with capacitors, etc.
>
> Now the problem is:
> Insert tape, capstan motor continues to run for a few seconds but the
clutch
> doesn't move, something is locking it up.  The head never starts turning
or
> the guide post assemblies never move and pull the tape out. After a few
> seconds, the tape is ejected.  The center led and end sensors are OK.
>
> With no manual, it is difficult to visualize what levers move, etc.  Any
> help would be appreciated on what I should look at.
>
> Thanks,
> Wally Heise
> South Isle Repair
> Isle, Mn.
>
>
>
> --------------------------------------------------------------------------
---
> Lost Password:
> http://www.tech-assist.org  and select "Login Problems?".
> Email Archives:
> //www.freelists.org/archives/techassist/


-----------------------------------------------------------------------------
Lost Password:
http://www.tech-assist.org  and select "Login Problems?".
Email Archives:
//www.freelists.org/archives/techassist/