Some of you may already do this but for others - when the set (rca-ge) wont start because of a corrupted eeprom i install a 8 pin socket at the eeprom location, plug in (half way -not tight) the new eeprom (this allows the set to come on). and while running pull the new eeprom then (with set still on ) plug in the original eeprom and retieve the values. Once you have written all the values (can turn off set ) swap the old eeprom for the new one and enter the values you retrieved, from the old one, into the new eeprom. Mike Gauthier Gauthier TV 44 Elm St. Amesbury Ma 01913 978 388 2213 413 425 6490 fax mailto:gauthiertv@xxxxxxxxxxxx ------------------------------------------ Help make your TechAssist database better! Submit your fixes here: http://circuitwork.com/techassist/tip/#tips ------------------------------------------ To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe Or send a BLANK email with unsubscribe in the SUBJECT field to the address above.