Sunil,
So what if it draws 1.2A instead of 0.5A?
How is the board powered? DCDC converter.


On Tue, Mar 5, 2013 at 8:27 PM, sunil bharadwaz
<sunil_bharadwaz@xxxxxxxxx>wrote:

> Hi All ,
> We are facing in rush current  issues in one of our boards .
> The board is rated for about 500 mA .However , it draws
> about 1200 mA for short duration of 40 to 50 usec.
>
> Adding a Load switch at the Power Source input is not
>
> helping much (not as much as required ) .
>
>
> Any thoughts or suggestions are welcome on this issue.
>
> Thanks much in Advance !!
>
> Regards
> Sunil.
>
> ------------------------------------------------------------------
> To unsubscribe from si-list:
> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
>
> or to administer your membership from a web page, go to:
> //www.freelists.org/webpage/si-list
>
> For help:
> si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
>
>
> List forum  is accessible at:
>                http://tech.groups.yahoo.com/group/si-list
>
> List archives are viewable at:
>                 //www.freelists.org/archives/si-list
>
> Old (prior to June 6, 2001) list archives are viewable at:
>                 http://www.qsl.net/wb6tpu
>
>
>


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List forum  is accessible at:
               http://tech.groups.yahoo.com/group/si-list

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: