Hi John,

Could you give me more details about the problem you've seen with Hspice 2001.4
and IBIS?

Also, the current version of Hspice is 2002.2.  It was released June 15.

Tracy Barclay
CAE, Hspice
Synopsys Inc.

> Hello Marlon,
>
> Make sure the IBIS buffer is in the same directory as your spice deck.
>
> Check the warning statements of the .lis file.
>
> The model call is case sensitive, make sure you have the correct call.
>
> If you are running in HSPICE version 2001.4, stop now and run it in an
> earlier version such as 2000.4.  There is a bug in the way 2001.4 handles
> IBIS buffers, but usually it gives you output
>
> John
>
> -----Original Message-----
> From: si-list-bounce@xxxxxxxxxxxxx
> [mailto:si-list-bounce@xxxxxxxxxxxxx]On Behalf Of ramroopsingh, marlon
> Sent: Tuesday, July 02, 2002 4:53 PM
> To: 'si list '
> Subject: [SI-LIST] IBIS ECL Clock issue.
>
> Good day all,
>         I am trying to run a simulation in HSpice using the On semi,
> mc100lve222_tq52_z.ibs model as the driver.  However I am not getting any
> output.  The model was tested in ICX and it passes, so I am under the
> assumption that the error is in my calling of the model.
>         The following test file shows how I am calling the IBIS model:
>
> ***** Test File to resolve IBIS issue******
>
> .OPT POST
> .OPTION PROBE
> .PROBE TRAN v(110) v(111)
> +       v(inp) v(inn)
>
> .tran 0.01n 16n
>
> *125MHz pulse
> VINP inp 0 PWL(0 vm 200p vh  3.8n vh 4.2n  vl  7.8n vl
> +8.2n vh 11.8n vh  12.2n vl 15.8n  vl 16n vm r)
>
> VINN inn 0 PWL (0 vm 200p vl  3.8n vl 4.2n  vh  7.8n vh
> +8.2n vl 11.8n vl  12.2n vh 15.8n  vh 16n vm r)
>
> .PARAM  VCC=3.3
> .param vh=1
> .param vl=0
> .param vm='(vh+vl)/2'
>
> b_output_ecl1 nd_pu 110 inp  nd_pc nd_gc
> + file='mc100lve222_tq52_z.ibs'  model='33V_OUT20'
>
> b_output_ecl2 nd_pu1 111 inn  nd_pc1 nd_gc1
> + file='mc100lve222_tq52_z.ibs'  model='33V_OUT20 '
>
> rterm1 110 0 50
> rterm2 111 0 50
>
> R100  100 0  0.1
> .END
>
>  If anyone sees any errors or can make any suggestions with regards to their
> experiences with this model, your feedback is greatly appreciated.
>
> Thanking you in advance,
>
> Marlon Ramroopsingh
>

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: