Hi Marlon, I guess you forgot the "pulldown" node. Try to substitute this line b_output_ecl1 nd_pu nd_pd 110 inp nd_pc nd_gc and a similar one for the other b-element. Hope this solves the problem, Luca On Tue, 02 Jul 2002 14:32:17 -0700 Tracy Barclay <Tracy.Barclay@xxxxxxxxxxxx> wrote: >=20 > Hi Marlon, >=20 > If this is a Tristat ECL Buffer, then you will need an enable signal. Th= e node > list for a tristate ECL buffer is: >=20 > nd_pu nd_out nd_in nd_en >=20 > the nd_pc and nd_gc nodes are optional. >=20 > P.S. I couldn't find this IBIS model on the On Semi web site, so, I didn= 't > actually run this netlist. >=20 > Tracy Barclay > CAE, Hspice > Synopsys Inc. >=20 > > Good day all, > > I am trying to run a simulation in HSpice using the On semi, > > mc100lve222_tq52_z.ibs model as the driver. However I am not getting a= ny > > output. The model was tested in ICX and it passes, so I am under the > > assumption that the error is in my calling of the model. > > The following test file shows how I am calling the IBIS model: > > > > ***** Test File to resolve IBIS issue****** > > > > .OPT POST > > .OPTION PROBE > > .PROBE TRAN v(110) v(111) > > + v(inp) v(inn) > > > > .tran 0.01n 16n > > > > *125MHz pulse > > VINP inp 0 PWL(0 vm 200p vh 3.8n vh 4.2n vl 7.8n vl > > +8.2n vh 11.8n vh 12.2n vl 15.8n vl 16n vm r) > > > > VINN inn 0 PWL (0 vm 200p vl 3.8n vl 4.2n vh 7.8n vh > > +8.2n vl 11.8n vl 12.2n vh 15.8n vh 16n vm r) > > > > .PARAM VCC=3D3.3 > > .param vh=3D1 > > .param vl=3D0 > > .param vm=3D'(vh+vl)/2' > > > > b_output_ecl1 nd_pu 110 inp nd_pc nd_gc > > + file=3D'mc100lve222_tq52_z.ibs' model=3D'33V_OUT20' > > > > b_output_ecl2 nd_pu1 111 inn nd_pc1 nd_gc1 > > + file=3D'mc100lve222_tq52_z.ibs' model=3D'33V_OUT20 ' > > > > rterm1 110 0 50 > > rterm2 111 0 50 > > > > R100 100 0 0.1 > > .END > > > > If anyone sees any errors or can make any suggestions with regards to = their > > experiences with this model, your feedback is greatly appreciated. > > > > Thanking you in advance, > > > > Marlon Ramroopsingh > > >=20 > ------------------------------------------------------------------ > To unsubscribe from si-list: > si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field >=20 > or to administer your membership from a web page, go to: > //www.freelists.org/webpage/si-list >=20 > For help: > si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field >=20 > List archives are viewable at: =20 > //www.freelists.org/archives/si-list > or at our remote archives: > http://groups.yahoo.com/group/si-list/messages=20 > Old (prior to June 6, 2001) list archives are viewable at: > http://www.qsl.net/wb6tpu > =20 --=20 Luca Giacotto <lgiacott@xxxxxxxxx> ***** Il modo pi=F9 sicuro di perdere una battaglia =E8 di non combatterla. ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu