Eric, Seems we have talked about signal lines a lot. Those lines are self-L dominated as we know. I don't remember any physics law prohibits L12>L1,or L2 other than K<=3D1 and some intuitive arguments. One special case can break the statement if we do not have solid foundation. If a law is pointed out or newly proven in general, the argument will be much easier. If not, it may be considered as a conjecture based on some observations at most.=20 How about when planes are involved? For example, for a package, L_vss is generally low referring to PCB GND. However, there are signals/planes that couple with VSS strongly.=20 Even for regular lines, is it possible to construct a case that breaks the statement? For example, when line loops cross each other in complex ways in 3D (not as simple as we have in regular designs).=20 Of course, numerical problems are always questionable. This is why the question confuses many of us. Is it because of the numerical errors or physically possible in some cases? Or in any case, we should check the numerical problems and force the vendor to satisfy us. Finding out when the statement is true (if not always) is also very helpful. Just some wild thoughts. Thanks. Mick -----Original Message----- From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx] On Behalf Of Eric Bogatin Sent: Saturday, October 29, 2005 8:58 AM To: si-list@xxxxxxxxxxxxx; ray.anderson@xxxxxxxxxx Cc: eric@xxxxxxxxxxxxxxx; susan@xxxxxxxxxxxxxxx Subject: [SI-LIST] Can L12 ever exceed L1 or L2 ?? Ray- I completely agree with Steve Weir's comment that it is not physically possible for L12 > L11, whether we use these terms as loop inductance elements or partial inductance elements. The self inductance is the number of loops of magnetic field lines that surround one conductor per amp of its current. The mutual inductance is the number of loops of magnetic field lines that surrounds both conductor, per amp of current in one. All the mutual field lines from one conductor must also, by definition surround its own conductor and be part of its self inductance. This is true for loop inductance or partial inductance. The real question is why your vendor supplied you with matrix elements where you got L21 =3D 3 x L11. I've gotten similar comments from other end users. The answer is that when the vendor ran their field solver, they did not use a fine enough mesh. If you have radically different conductor geometries, like a short, wide conductor and a long, meandering trace, you will often see on the first pass calculation of the field solver that the partial self inductance of the short trace is less than the partial mutual between them.=20 Your vendor needs to refine their mesh. When the mesh is refined so that the matrix elements do not change by more than about 1% for a 10-20% increase in mesh elements in the high field regions, the mesh is refined enough. Perhaps if your vendor were to read chapter 6 in my book Signal Integrity-Simplified, they would have a better chance of providing you more accurate and meaningful models. Hope this helps. --eric *************************************** Eric Bogatin Bogatin Enterprises OnLine Lectures on Signal Integrity 26235 w 110th terr Olathe, KS 66061 v:913-393-1305 cell: 913-424-4333 f:913-393-0929 e:eric@xxxxxxxxxxxxxxx www.BeTheSignal.com <http://www.BogEnt.com>=20 Signal Integrity- Simplified published by Prentice Hall ***************************************** Msg: #7 in digest Subject: [SI-LIST] Can L12 ever exceed L1 or L2 ?? Date: Fri, 28 Oct 2005 12:21:06 -0700 From: "Ray Anderson" <ray.anderson@xxxxxxxxxx> A question for the E&M gurus on the list: =20 Are there any conditions (pathological or not) that the mutual inductance between two conductors can be greater than the self inductance of either one? =20 Since L12 =3D k * sqrt(L1*L2) and the coupling factor k must be -1 < k < 1 then this would seem to imply that L12 must be less than or equal to geometric mean of the self inductances. However this leaves open the possibility the Lm could be > than one or the other which flies in the face of the commonly made assertion that Lm must be less than either. It seems that there must be other qualifying statements to made regarding the relationship to the self and mutual inductances. =20 Going back to some of the basic fundamental relationships (such as Grover's formulas) I can convince myself that for circular conductors L12 must be less than or equal to either L1 or L2, but how about the mutual coupling between some other structures say a signal trace and large planar structure that isn't intended to be be a signal return path but very well may be ? =20 I've got a field solver reporting Lm being 2 to 3 times Lself on one particular problem. I'm trying to determine if the solver is having a difficult time dealing with the particular geometries involved or if it is indeed possible despite the common wisdom to the contrary. =20 Any comments one way or the other are appreciated. =20 Regards, =20 -Ray =20 =20 Raymond Anderson Senior Signal Integrity Staff Engineer Product Technology Department Advanced Package R&D Xilinx Inc. -- Binary/unsupported file stripped by Ecartis -- -- Type: application/ms-tnef -- File: winmail.dat ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List FAQ wiki page is located at: http://si-list.org/wiki/wiki.pl?Si-List_FAQ List technical documents are available at: http://www.si-list.org List archives are viewable at: =20 //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu =20 ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List FAQ wiki page is located at: http://si-list.org/wiki/wiki.pl?Si-List_FAQ List technical documents are available at: http://www.si-list.org List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu