[pure-silver] Re: Introduction and Sodium fixer question

  • From: "titrisol" <dmarc-noreply@xxxxxxxxxxxxx> (Redacted sender "titrisol" for DMARC)
  • To: pure-silver@xxxxxxxxxxxxx
  • Date: Fri, 8 Nov 2019 14:29:22 +0000 (UTC)

 ILFORD recommends only 1:00 in their rapid fixer, I normally leave FB paper in 
the fixer for a while longer (2 - 4 minutes) since I'm multitasking in the 
darkroomhttps://www.ilfordphoto.com/amfile/file/download/file/1748/product/735/
Ilford recommends a 3 bath rinse water-wash aid-water ; see page 3 of the pdf 
of their optimal permanence sequence 
PABLO    On Friday, November 8, 2019, 09:01:26 AM EST, Miha Golobic 
<miha.golobic@xxxxxxxxx> wrote:  
 
 2x5 min seems on the long side to me, however with your extensive instructions 
I may test it in the near future to be on the safe side.Thank you again for 
your time.Miha

V V čet., 7. nov. 2019 ob 23:06 je oseba `Richard Knoppow 
<dickburk@xxxxxxxxxxxxx> napisala:

    I am not sure how long the fixing for fiber paper should 
take. It takes longer than for RC paper because some of the 
emulsion gets into the baryta layer so the fixer must penetrate 
it. The fixing times are shorter than those recommended in the 
old books because they took into account the hardening action. 
Not needed for modern papers. I would give fiber something like 
five minutes in each bath. Then rinse or short wash, then hypo 
clear, then wash as you have been doing, Kodak recommends 10 
minutes for single weight, 20 minutes for double weight and 30 
minutes for premium weight. This should be in a washer that 
provides a continuous flow of water.
   There is a test for residual hypo that uses a solution of 
silver nitrate. Kodak HT-2. If there is much hypo it leaves a 
permanent stain. There is another test for excess silver, Kodak 
ST-1,  in the emulsion, a weak solution of sodium sulfide. The 
sulfide stains the halide as well as the metallic silver. It 
leaves a yellow or brown stain similar to the hypo test. There 
are more elaborate tests that give quantitative accuracy but they 
are much more complex and the above simple tests are good enough 
to confirm the fixing and washing process.
    There is another test for the amount of silver dissolved in 
the hypo, Kodak FT-1, using Potassium iodide. However, the amount 
of silver in the fixing baths depends on whether a single or two 
bath fixer is used and to some degree on whether a hypo clearing 
agent is used (increases the allowable amount of silver.
    I am posting the formulae and instructions:
Kodak FT-1 Fixer Test Solution
Water (at 80F or 27C)..........750.0 mL
Potassium iodide...............190.0 grams
Water to make....................1.0 Liter

For a single bath or the first bath of a two bath system take 5 
drops of FT-1 add 5 drops of fixing bath and 5 drops of water. 
Discard if a yellow-white cloud forms instantly.
    For the second bath of a two bath system take 5 drops of 
FT-1, add 5 drops of fixing bath and add 15 drops of water.
    ST-1 can also be used to test film for excess silver. Dilute 
the stock with nine parts water. Place a drop on a clear part of 
the emulsion and allow to sit for 2 or 3 minutes. Then blot off. 
Any yellow stain is an indication of too much silver left  in the 
emulsion.
Kodak HT-2 Hypo Test Solution
Water..............750.0 mL
Acetic acid, 28%...125.0 mL
Silver nitrate...... 7.5ml
Water to make........1.0 Liter
    Use distilled water. Any impurities can cause the silver 
nitrate to come out of solution.
    A few drops of the solution should be placed in a clear area 
of the image and allowed to stand for two minutes. It should 
leave either a slight yellow stain or no stain. The stain is 
permanent so the test is best done on a scrap processed with the 
prints made.
    Because silver nitrate is expensive you can make up a 
fraction of this formula. This solution will keep about 6 months 
in the dark.
     I think these tests are a bit of overkill although the fixer 
test can be useful in keeping track of how much the fixing bath 
has been used.
On 11/7/2019 11:56 AM, Miha Golobic wrote:

Great, thank you. So for FB paper 2-3 min in each bath (sodium 
fix no hardener), followed by 5 min wash, hypo clear, followed by 
30-40 min wash (or water exchange) sounds about right as well.

So far my regime was 1-2 min in Ilford Hypam 1+4, single bath, no 
hypo clear, wash up to 1 hour.

V sre., 6. nov. 2019 20:59 je oseba `Richard Knoppow 
<dickburk@xxxxxxxxxxxxx <mailto:dickburk@xxxxxxxxxxxxx>> napisala:


-- 
Richard Knoppow
dickburk@xxxxxxxxxxxxx
WB6KBL
=============================================================================================================
To unsubscribe from this list, go to www.freelists.org and logon to your 
account (the same e-mail address and password you set-up when you subscribed,) 
and unsubscribe from there.

  

Other related posts: