Richard:

Thanks for your reply. What software version did they upgraded to ? Was it an 
upgrade on the OPTOS camera, or just an upgrade on the review software? We have 
version 2.4.0.129 on the review software.

Please let me know, and I'll pass on to upper management, so that we could 
upgrade it too. What was the cost?

Sincerely,

Nilo

Jules Stein, UCLA

--- On Tue, 11/27/12, Hackel, Richard <rhackel@xxxxxxxxxxxxx> wrote:

From: Hackel, Richard <rhackel@xxxxxxxxxxxxx>
Subject: [optimal] Re: Time frame from OPTOS exported images
To: "optimal@xxxxxxxxxxxxx" <optimal@xxxxxxxxxxxxx>
Date: Tuesday, November 27, 2012, 1:30 PM



 
 




We worked with Optos closely on this, and they finally got it to work really 
well, and they upgraded our software in October. Now, when we close the 
procedure
 on the Optos camera, it automatically uploads the entire procedure to our 
OIS/Merge/Symphony database with the correct time stamp for the FA, in order 
and high quality. There were issues before with the DICOM image quality but 
they were able to fix that too. 
   
Richard 
Richard Hackel, CRA, FOPS 
Clinical Instructor and 
Director of Ophthalmic Photography, 
Kellogg Eye Center 
Adjunct Assistant Professor of Art, 
School of Art and Design 
University of Michigan 
1000 Wall Street 
Ann Arbor, Michigan 48105 
734-936-2283 
email: rhackel@xxxxxxxxx 
   
   
   


From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx]
On Behalf Of Lee, Katherine K.

Sent: Tuesday, November 27, 2012 4:15 PM

To: optimal@xxxxxxxxxxxxx

Subject: [optimal] Re: Time frame from OPTOS exported images 


   


We've also expressed our concern. Our rep is not sure if that change will be in 
the new update or not. It's not a problem if patient is seen on the same floor,
 where we have review stations at most computers. It could become an issue at 
satellite offices, however. 



  


Katherine K Lee COT 


Storm Eye Institute 


843-792-2764 


fax   792-8865 


pager  17576 


intended only
 for the use of the individual or entity to which it is addressed and may 
contain information that is privileged, confidential, and exempt from 
disclosure.  If the reader is not the intended recipient or an employee 
responsible for delivering the message to
 the intended recipient, you are notified that any dissemination, distribution, 
or copying of this communication is strictly prohibited.  If you received this 
communication in error, please notify us immediately by telephone and notify 
the previous sender by
 email.  



  





From:
optimal-bounce@xxxxxxxxxxxxx [optimal-bounce@xxxxxxxxxxxxx] On Behalf Of 
Peterson John C [JPeterson@xxxxxxxxxxxx]

Sent: Tuesday, November 27, 2012 4:02 PM

To: 'optimal@xxxxxxxxxxxxx'

Subject: [optimal] Re: Time frame from OPTOS exported images 


No, the time stamps reside in the file name only. Even there it's just using 
the computer clock, not starting from 0:00. We've passed on our concerns and 
the field reps
 are trying to impress the importance on to their programmers. Work in 
progress. 
  
John 
********

John C. Peterson, BS, CRA

Senior Ophthalmic Photographer

UW Health Eye Clinic

2880 University Ave., Rm. 246

Madison, WI 53705

(608) 263-7163



"If you want to go fast, go alone. If you want to go far, go together." 

  

   



From:
optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx]
On Behalf Of Nilo Davila

Sent: Tuesday, November 27, 2012 2:58 PM

To: optimal@xxxxxxxxxxxxx

Subject: [optimal] Time frame from OPTOS exported images 




Can you include the FA time frame on the OPTOS exported images?




Nilo



UCLA 




   



**********************************************************

Electronic Mail is not secure, may not be read every day, and should not be 
used for urgent or sensitive issues 

Other related posts: