Thanks for the advice regarding the blast hole size. I'm in London at present but will try opening it out next week (and fit a spark arrester) in time for the BHR steam Gala on 2nd July. Cheers Ken ----- Original Message ---- From: Barrie Purslow <bpduo@xxxxxxxxxxxxx> To: modeleng@xxxxxxxxxxxxx Sent: Friday, 16 June, 2006 11:51:58 AM Subject: [modeleng] Re: Conway Hi Ken, I have had this problem and solved it by increasing the diameter of the blast pipe. I did it in increments of 0.5mm until I had the desired amount of draw on the fire. Cheers, Barrie Purslow Warrington U.K. ----- Original Message ----- From: "Kenneth Swales" <kenwillowbend@xxxxxxxxx> To: <modeleng@xxxxxxxxxxxxx> Sent: Thursday, June 15, 2006 8:42 PM Subject: [modeleng] Conway > Hi > > I had Conway running this evening and I have a problem with the engine > blower (not the steam blower). It's so fierce that even when running I'm > constantly blowing the safety valve. Also I constantly have a shower of > sparks. This is enough to draw the fire into the bottom of the smokebox. > The chimney top is getting so hot, it's gone a purple colour. > > Do I increase the jet size or reduce it to reduce the draught from the > engine? > > Thanks for any assistance on this problem. > > Cheers > > Ken > > MODEL ENGINEERING DISCUSSION LIST. > > To UNSUBSCRIBE from this list, send a blank email to, > modeleng-request@xxxxxxxxxxxxx with the word "unsubscribe" in the subject > line. > > > > -- > No virus found in this incoming message. > Checked by AVG Free Edition. > Version: 7.1.394 / Virus Database: 268.8.3/360 - Release Date: 09/06/2006 > > MODEL ENGINEERING DISCUSSION LIST. To UNSUBSCRIBE from this list, send a blank email to, modeleng-request@xxxxxxxxxxxxx with the word "unsubscribe" in the subject line. MODEL ENGINEERING DISCUSSION LIST. To UNSUBSCRIBE from this list, send a blank email to, modeleng-request@xxxxxxxxxxxxx with the word "unsubscribe" in the subject line.