[ibis-quality] Re: First pass documentation for VT/Ramp/ComponentSection/Model limitations

  • From: Barry Katz <bkatz@xxxxxxxxxx>
  • To: ibis-quality@xxxxxxxxxxxxx
  • Date: Tue, 03 Dec 2002 07:25:48 -0500

Word doc uploaded to web.

Barry

Barry Katz wrote:
>  
> 
> All,
> 
> I have put this in outline form for now. I want to make sure I have all the
> points highlighted prior to formatting into agreed upon template.
> 
> Barry
> 
> 
> 
> Component Section
> 
>   * Level 0 
>     * Package parasitics  
>       * Must be defined on a component 
>     
>       * Optional on pins, but if not defined must use NA NA NA 
>       * Parasitics must be reasonable L <10nF, C <20pF, R <1 ohm 
>       * External Package model
>         
>     
>     * Physical/Logical/Model Pin Mapping 
>       * Models must exist in file or refer to Model Selector 
>       * Pin names should not exceed 20 characters (to change?)
>         
>       * No Connects represented with NC
>         
>       * Power pins must be indicated POWER 
>       * Gnd pins must be indicated GND 
>       * Special Pins (e.g. analog) to be represented by NC with note 
>     
>     * Diff pin sections 
>       * If defined, physical pins must exist 
>       * Vdiff must be defined and reasonable 
>       * Skew data must be defined and reasonable
>         
>       * Same models must exist on both pins of a diff pair 
>     
>     * Model Selector 
>       * All models must be valid 
>       * First should be default
>         
>     
>   
>   * Level 1 
>     * Package parasitics  
>       * Package parasitics are validated against data sheet 
>     
>     * Physical/Logical/Model Pin Mapping 
>       * Mapping is validated to be complete and correct 
>       * Power, Gnd, NC pins validated 
>       * All pins defined 
>     
>     * Model Selector 
>       * First model confirmed to be default
>         
>     
>   
> VT Curves/Ramp Data
> 
> 
>   * Level 0 
>     * Should have four VT curves 
>       * 50 Ohm Pullup (Pullup Voltage = Voltage) 
>         * Rising 
>         * Falling 
>       
>       * 50 Ohm Pulldown 
>         * Rising 
>         * Falling 
>       
>       * Noted Exceptions 
>         * TBD 
>       
>     
>     * VT Curves and Ramp should be consistent 
>     * VT Curves must be monotonic
>       
>     * VT Should be consistent with IV curves 
>     * Ramp data should not be zero 
>     * No negative ramp values
>       
>   
> 
>   * Level 1 
>     * Ramp should be measured from 20-80% of swing 
>     * Ramp typ/min/max order verified 
>     * VT Curves must be visually inspected 
>       * Should be well behaved with continuous second derivative 
>       * VT point density should be increased in areas with non-zero second
> derivative
>         
>       * Excess VT points in beginning and end of VT curves should be removed
> 
>         * Relative position between all curves should be maintained 
>         * Final DC value must be achieved 
>       
>     
>   
>     * Simulations run and confirmed?  New section?
>       
>   
> 
> Model Limitations
> 
>   * Level 0 
>     * Identification of any known limitations in model 
>       * Examples include PVT 
>       * Keywords that may be placeholders(such as Vih/Vih) 
>       * LVDS restrictions 
>       * etc
>         
>     
>   
> 
> ---------------------------------------------------------------------
> IBIS Quality website:  http://www.sisoft.com/ibis-quality
> IBIS Quality archives: //www.freelists.org/archives/ibis-quality
> To unsubscribe send an email:
>   To: ibis-quality-request@xxxxxxxxxxxxx
>   Subject: unsubscribe
> 

-- 
Barry Katz
President & CTO
Signal Integrity Software
6 Clock Tower Place, Suite 250
Maynard, MA 01754
Office: 978 461-0449 x19
Cell: 978 618-9078

---------------------------------------------------------------------
IBIS Quality website:  http://www.sisoft.com/ibis-quality
IBIS Quality archives: //www.freelists.org/archives/ibis-quality
To unsubscribe send an email:
  To: ibis-quality-request@xxxxxxxxxxxxx
  Subject: unsubscribe

Other related posts:

  • » [ibis-quality] Re: First pass documentation for VT/Ramp/ComponentSection/Model limitations