Word doc uploaded to web. Barry Barry Katz wrote: > > > All, > > I have put this in outline form for now. I want to make sure I have all the > points highlighted prior to formatting into agreed upon template. > > Barry > > > > Component Section > > * Level 0 > * Package parasitics > * Must be defined on a component > > * Optional on pins, but if not defined must use NA NA NA > * Parasitics must be reasonable L <10nF, C <20pF, R <1 ohm > * External Package model > > > * Physical/Logical/Model Pin Mapping > * Models must exist in file or refer to Model Selector > * Pin names should not exceed 20 characters (to change?) > > * No Connects represented with NC > > * Power pins must be indicated POWER > * Gnd pins must be indicated GND > * Special Pins (e.g. analog) to be represented by NC with note > > * Diff pin sections > * If defined, physical pins must exist > * Vdiff must be defined and reasonable > * Skew data must be defined and reasonable > > * Same models must exist on both pins of a diff pair > > * Model Selector > * All models must be valid > * First should be default > > > > * Level 1 > * Package parasitics > * Package parasitics are validated against data sheet > > * Physical/Logical/Model Pin Mapping > * Mapping is validated to be complete and correct > * Power, Gnd, NC pins validated > * All pins defined > > * Model Selector > * First model confirmed to be default > > > > VT Curves/Ramp Data > > > * Level 0 > * Should have four VT curves > * 50 Ohm Pullup (Pullup Voltage = Voltage) > * Rising > * Falling > > * 50 Ohm Pulldown > * Rising > * Falling > > * Noted Exceptions > * TBD > > > * VT Curves and Ramp should be consistent > * VT Curves must be monotonic > > * VT Should be consistent with IV curves > * Ramp data should not be zero > * No negative ramp values > > > > * Level 1 > * Ramp should be measured from 20-80% of swing > * Ramp typ/min/max order verified > * VT Curves must be visually inspected > * Should be well behaved with continuous second derivative > * VT point density should be increased in areas with non-zero second > derivative > > * Excess VT points in beginning and end of VT curves should be removed > > * Relative position between all curves should be maintained > * Final DC value must be achieved > > > > * Simulations run and confirmed? New section? > > > > Model Limitations > > * Level 0 > * Identification of any known limitations in model > * Examples include PVT > * Keywords that may be placeholders(such as Vih/Vih) > * LVDS restrictions > * etc > > > > > --------------------------------------------------------------------- > IBIS Quality website: http://www.sisoft.com/ibis-quality > IBIS Quality archives: //www.freelists.org/archives/ibis-quality > To unsubscribe send an email: > To: ibis-quality-request@xxxxxxxxxxxxx > Subject: unsubscribe > -- Barry Katz President & CTO Signal Integrity Software 6 Clock Tower Place, Suite 250 Maynard, MA 01754 Office: 978 461-0449 x19 Cell: 978 618-9078 --------------------------------------------------------------------- IBIS Quality website: http://www.sisoft.com/ibis-quality IBIS Quality archives: //www.freelists.org/archives/ibis-quality To unsubscribe send an email: To: ibis-quality-request@xxxxxxxxxxxxx Subject: unsubscribe